R3-2 Transponders | R3-2 Serial Reader Specifications | R3-2 Industrial Protocols Reader Specifications
RR3-2 Ethernet Interface Specifications | Hand Held Readers/Programmers | Specialty Readers | Antenna Specifications | Customer List | R3-2 Home
R3 Serial Reader Specifications
Model 7000E series Reader Writer
Used by itself as a simple Serial peripheral, this Reader outputs standard RS232.

LED for power and read indication. LED can be optioned for relay driver. |
Model 7050E (E signifies Enclosure)
Using RS485, 32 of these Readers can be multi-dropped to a single serial port.

LED for power and read indication. LED can be optioned for relay driver. |
Connectors:
Thumb pressure terminal strips on PCB Cable glands on Enclosure |
Housing:
NEMA 4X with clear lid for quick troubleshooting Measuring 4.5" x 3.5"x 2.1875" |
Voltage:
+7 to +28 volts DC |
Optional Metal Housing |
Current:
200 mA (max) 125 mA (typ) |
Temperature:
Operating -40 to +55 degrees C
Non-Operating -55 to +85 degrees C |
| Model |
Description |
Serial Connection |
Power Connection |
| 7000E |
RS232 Reader |
Pigtail Wiring |
Pigtail Wiring |
| 7001E |
RS232 Reader |
Pigtail Wiring |
Power Jack |
| 7002E |
RS232 Reader |
9 PIN Connector |
Pigtail Wiring |
| 7003E |
RS232 Reader |
9 PIN Connector |
Power Jack |
| 7050E |
RS485 Reader |
NA |
Pigtail Wiring |
| 7051E |
RS485 Reader |
NA |
Power Jack |
| PS12PJ |
AC Power Supply with Power Jack Connector |
| PS12PT |
AC Power Supply with Pigtail Wiring |
Reader Model numbers must be ordered with the suffix RO for Read Only or RW for Read Write dependent upon the style of Tag being ordered. The Tag specifications list whether a Tag is RO or RW.
For example, ordering Model 1764 Clear Laminate Flexible Disc Tag in a Read Only format you would have to specify Model 700xE-RO on your order (x being a variable to the exact Reader model number). Ordering Model 1764 Clear Laminate Flexible Disc Tag in a Read Write format you would have to specify Model 700xE-RW on your order.
You can always use a Read Write Tag in a Read Only application by simply not using the Write function, but cannot use a Read Only Tag in a Read Write application.
The "E" suffix stands for our standard NEMA 4X Enclosure. Drop the "E" to order Readers at an OEM PCB level. Add "EM" to order Readers in a metal enclosure. Add "IA" to have Internal Antenna Mounted to the lid of the Enclosure.
12' of Antenna cable is standard. 19' or 33' of Antenna cable is also available but must be specified by adding the suffix -19 or -33. 19' cable option garners 25% less read range, 33' cable option garners 50% less read range, on average. Antenna cables may not be altered, cut down or added to, as they are a part of the overall tuned signal.